What is the minimum size of a down conductor for lightning protection?
The down conductor is properly listed in the standard as a “Main Conductor Cable”. Class I – Copper: Minimum Gauge is 2 AWG, with a minimum individual strand size of 17 AWG. Class II – Copper: Minimum Gauge is 00 AWG, with a minimum individual strand size of 17 AWG.
What type of wire is used for lightning protection?
Copper and aluminum main cable conductors for lightning protection are designed to a smooth weave or rope-lay standard using smaller gauge individual wires. This construction allows a maximum surface area per unit weight of conductor to accommodate lightning which travels quickly on the surface.
How much area does a lightning arrester cover?
On structures less than 30 metres (about 100 feet) in height, a lightning rod provides a cone of protection whose ground radius approximately equals its height above the ground. On taller structures, the area of protection extends only about 30 metres from the base of the structure.
Is standard for lightning arrester?
IEC 62305 – Protection Against Lightning, is the apex level document that informs the standards for lightning protection around the world. The IEC 62305 standard covers the regulations required for the protection of equipment and structures from the effects of both direct and indirect lightning strikes.
What is the size of lightning arrester earth strip?
lightning discharge receiver shall be effectively connecte earth pit by Tinned Copper Strip of 25X3 mm.
What material should a lightning conductor be made of?
The main attribute common to all lightning rods is that they are all made of conductive materials, such as copper and aluminum. Copper and its alloys are the most common materials used in lightning protection.
Why do modern homes not have lightning rods?
Perhaps it’s because the chance of a lightning strike is, for most houses, quite low. However, most high buildings and other structures do have some kind of lightning protection system incorporated into them.
How is lightning arrester height calculated?
Length of Building (L) = 60 Meter. Width of Building ( W ) = 28 Meter. Height of Building (H) = 23 Meter….Calculate Lightning Protection for Building / Structure.
Degree of Isolation | Factor |
---|---|
Structure in a large area having greater height | 0.4 |
Structure located in a area of the same height | 1 |
Structure completely Isolated | 2 |
How do you measure lightning arresters?
The two most important factors used to select an arrester rating are the system voltage and the neutral grounding configuration of the source transformer. These tables assume that the maximum duration and amplitude of the worst-case overvoltage during a line-to-ground fault are unknown.
Is your lightning protection system UL compliant?
Lightning protection systems must meet current requirements and be installed correctly to provide optimal protection. UL examines lightning protection system components and completed installations for compliance with UL’s internationally recognized Standards for lightning protection systems, or other recognized national standards.
Are the conductors UL listed?
All Conductors are UL Listed. Conductor is sold by the foot. Enter the number of feet you wish to purchase in the “ADD TO QUOTE” box.
What types of conductors are available in lightlightning protection?
Lightning Protection Conductor and Secondary Conductors are available in Class I and Class II. Conductor is available in Bare Copper, Bare Aluminum, or Tin-Plated Copper.
How long does the UL lightning protection Journeyman certification last?
Candidates who successfully complete the UL Lightning Protection Journeyman Certification or UL Lightning Protection Master Certification receive a certificate that is valid for three years. In addition, each individual’s name is included in UL’s website listing of industry professionals having achieved this credential.