How do I recover a failed logical drive?
Re: Recovery of logical drive failed Take complete data backup and system state backup. Delete the logical drive and recreate the logical drive and reinstall the operating system. and restore the data. This should solve your problem.
How do I enable logical drive on Social Security?
Open HPE SSA. Select a controller from the Devices menu. The Actions panel appears. Under Configure>Logical Devices, choose the array with logical drives.
Do not remove the drive Removing the drive causes one or more of the logical drives to fail?
Removing the drive does not cause a logical drive to fail. The drive is a member of one or more logical drives.
How do I reset my HP Intelligent Provisioning?
From the main Intelligent Provisioning screen, click Perform Maintenance, and then follow the onscreen prompts to begin erasing the system. Click One-button secure erase.
How do I enable SSD smart path?
HPE SSD smart path is enabled by default when user create an array. Open the Configure panel by doing one of the following: Choose a device and click Configure in the quick navigation menu. Select an available device from the Home screen, and then click Configure under the available options.
How do I check if my HP raid is rebuilt?
Perform the following steps to check the Rebuild Status or Percentage: 1. Open System Management Homepage of the server, either locally or remotely. 2. Select Smart Array controller xxx under Storage box for which the hard drive is changed.
How do I find RAID configuration on HP Proliant server?
See if the system has the hpssacli command installed.
- If so, you can run hpssacli ctrl all show config to get the configuration of the array.
- If this command is not installed, you may want to install it…
How do I enable intelligent Provisioning in BIOS?
To re-enable Intelligent Provisioning:
- Reboot the server and, when prompted, press F9 to access the UEFI System Utilities.
- From the System Utilities screen, select System Configuration → BIOS/Platform Configuration (RBSU) → Server Security → Intelligent Provisioning (F10 Prompt) and press Enter.
- Select Enabled.
How do I update my HP ProLiant intelligent Provisioning?
To update Intelligent Provisioning and component firmware:
- Select Firmware Update in the Perform Maintenance window.
- After the system retrieves the firmware data, it checks the installed hardware components to suggest items to update.
- Select the items to update, and then click Install.
What is HP SSD smart path?
HP SSD Smart Path enables an optimized data path to high performance solid state drives. The optimized. path bypasses the controller’s RAID processing components and sends I/O directly to the drives. To enable or disable HP SSD Smart Path: 1.